Does a stovepipe need special clearance to combustibles.
Wood burning stove pipe clearance.
Details about pellet stove clearance distances and pellet stove chimney or vent termination clearance distances from various building features are now found.
Us stove 1 200 sq.
Clearances far stove and stovepipe from walls and floor.
Clearances indicated in table 1 below are the minimum clearances from wood burning stoves to unprotected combustible wall and ceiling surfaces.
The clearance for an uncertified radiant stove is 1200 mm 48 in and for a stove with a sheet metal jacket or casing the clearance is 900 mm 36 in.
Check the clearance chart.
Steel stove is also one of the cleanest burning epa certified stoves on the market without catalyst.
This beautiful 3 16 in.
A 6 inch pipe would need a 42 inch diameter hole cut through a.
At pellet stove manuals.
For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls.
The ashley hearth aw3200e p is an extra large wood the ashley hearth aw3200e p is an extra large wood burning stove with 152 000 btus of heat.
Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles.
Many think stovepipe can run from the wood stove right up through the ceiling and roof.
Just because the stoves clearances can be reduced using a rear heat shield does not mean that the pipes clearances automatically fall into place.
Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall.
Defender wood burning stove with legs blower us1100e bl.
Clearance clearance select items sale sale select items compare castle pellet stoves serenity freestanding 1500 sq.
Wood stove wall clearances primer.
Any area within 36 inches of the wood stove should be covered as shown in figure 2.
Posted on oct 18 2015 at 9 14 am.
How to apply nfp 211 to wood stove fire clearances.
Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Use a thimble the clearance must be three times the pipe diameter.
Table 1 minimum clearances from wood burning stoves to.
4 1 41 was save.
Other combustibles other combustible materials such as firewood paper curtains and plastics should be kept at least 36 inches from the stove.
Stovepipes like fireplaces wood burning stoves must be vented to the outside of the building.
Stove pipe don t forget to check the pipe clearances.
The clearances are large because they apply to all shapes sizes and designs of stoves that have not been tested to determine the actual clearances.
Product rating is 4.